3.20 Fungus. The manufacturer shall certify that all external materials are fungus resistant or shall perform the
test specified in 4.7.16. When tested as specified in 4.7.16, there shall be no evidence of fungus growth on the
external surface of the capacitor.
3.21 Resistance to solvents. When capacitors are tested as specified in 4.7.17, there shall be no evidence of
mechanical damage, and the marking shall remain legible.
Insulation resistance:
Shall be not less than the initial requirement.
*
Capacitance:
Shall change not more than 0.5 percent of nominal value or 0.5 pF, whichever is
greater, from the initial value obtained when measured as specified in 4.7.5.
Dissipation factor:
Shall not exceed the initial requirement.
Visual examination:
There shall be no evidence of mechanical damage.
3.22 Resistance to soldering heat. When tested as specified in 4.7.18, capacitors shall meet the following
requirements:
Insulation resistance:
Shall be not less than the initial requirement.
Capacitance:
Shall change not more than 0.5 percent of nominal value or 0.5 pF, whichever is
greater, from the initial value obtained when measured as specified in 4.7.5.
Dissipation factor:
Shall not exceed the initial requirement.
Visual examination:
There shall be no evidence of mechanical damage
3.23 Moisture resistance. When tested as specified in 4.7.19, capacitors shall meet the following requirements:
Visual examination:
No mechanical damage. Marking shall remain legible.
Insulation resistance:
Unless otherwise specified (see 3.1), not less than 10 percent of the initial 25°C
requirement.
Unless otherwise specified (see 3.1), change not to exceed ±10 percent from initial
Capacitance:
measured value.
3.24 Life. When tested as specified in 4.7.20, capacitors shall meet the following requirements, as applicable.
3.24.1 2,000 hour (qualification inspection) (see 4.7.20.1).
Insulation resistance:
Shall be not less than the initial requirement.
*
Capacitance:
Shall change not more than the percent specified (see 3.1) of nominal value or 0.5 pF,
whichever is greater, from the initial value obtained when measured as specified in
Dissipation factor:
Shall not exceed the value specified (see 3.1).
Visual examination:
There shall be no evidence of mechanical damage.
6