MIL-PRF-55365H
4.7.19 Life (see 3.22). Capacitors shall be tested in accordance with method 108 of MIL-STD-202. The following
details and exceptions shall apply:
a. Method of mounting: As specified in 4.7.1.
b. Test temperature and tolerance:
(1) For qualification: Capacitors being subjected to the test of group V of table VI shall be at +125°C +4°C,
-0°C. Capacitors being subjected to the test of group VI of table VI shall be tested at +85°C +4°C, -0°C.
(2) For group C (2,000 hours proof): Capacitors shall be tested at +125°C +4°C, -0°C.
c. Operating conditions: A minimum of dc rated voltage (see 3.1) or a minimum of derated voltage at +125°C
(see table I), as applicable, shall be applied gradually (not to exceed 5 minutes either by a slow buildup of
the voltage or through a resistor which shall be shorted out within 5 minutes). Voltage shall be applied
continuously, except for measurement periods. The impedance of the voltage source, as seen from the
terminals of each capacitor, shall not exceed 3 ohms. Storage batteries or an electronic power supply
capable of supplying at least 1 ampere when a capacitor is shorted shall be used.
d. Test condition letter: F (2,000 hours).
e. Measurements during the exposure: DC leakage at the applicable high test temperature shall be measured
as specified in 4.7.6 at 0 hour; 240 hours +72, -24 hours; 1,000 hours +72, -24 hours; and 2,000 hours +96,
-0 hours.
Measurement after exposure: Capacitors shall be returned to the inspection conditions specified in 4.3, and
f.
visually examined for evidence of mechanical damage; dc leakage, capacitance, and dissipation factor shall
4.7.19.1 Extended life (exponential only). Capacitors shall be tested as specified in 4.7.19, except that the test
temperature shall be +85°C +4°C, -0°C, and the duration of the test shall be 10,000 hours. DC leakage shall be
measured as specified in 4.7.6 at +85°C +4°C, -0°C at 0 hour; 240 hours +72, -24 hours; 1,000 hours +72, -24 hours;
2,000 hours +96, -24 hours; and every 2,000 hours +96, -24 hours thereafter until 10,000 hours +120, -0 hour have
elapsed. Final measurements shall be as specified in 4.7.19f.