MIL-PRF-55365H
*
Step 2 (-55°C):
Capacitance
Shall change not more than ±10 percent (±20 percent for CWR15) from the
step 1 measured value.
As specified in 3.11.
Dissipation factor
*
Step 3 (+25°C):
DC leakage
As specified in 3.9.
Capacitance
Shall change not more than ±5 percent (±10 percent for CWR15) from the
step 1 measured value.
Dissipation factor
As specified in 3.11.
*
Step 4 (+85°C):
DC leakage
As specified in 3.9.
Capacitance
Shall change not more than ±10 percent (±15 percent for CWR15) from the
step 1 measured value.
Dissipation factor
As specified in 3.11.
*
Step 5 (+125°C):
DC leakage
As specified in 3.9.
Capacitance
Shall change not more than ±15 percent (±20 percent for CWR15) from the
step 1 measured value.
As specified in 3.11.
Dissipation factor
*
Step 6 (+25°C):
DC leakage
As specified in 3.9.
Capacitance
Shall change not more than ±5 percent (±10 percent for CWR15) from the step
1 measured value.
Dissipation factor
As specified in 3.11.
ESR (when specified, see 3.1)
As specified in 3.17.
3.20 Surge voltage (exponential only, see 3.1). When tested as specified in 4.7.17, capacitors shall meet the
following requirements:
*
As specified in 3.9.
DC leakage
Shall change not more than ±5 percent from the initial measured value.
Capacitance
Dissipation factor
As specified in 3.11.
ESR (when specified, see 3.1)
As specified in 3.17.
3.21 Surge current (optional). This test is a user specified option that is ordered by adding a letter to the
PIN (see 1.2.1.7). When tested as specified in 4.7.18, capacitors shall meet the following requirements:
DC leakage
As specified in 3.9.
Capacitance
As specified in 3.10.
Dissipation factor
As specified in 3.11.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business