MIL-DTL-3965H
4.6.2.1.4 Noncompliance. If a sample fails to pass group C inspection, the supplier shall take corrective action on
the materials or processes, or both, as warranted, and on all units of product which can be corrected and which were
manufactured under essentially the same conditions, with essentially the same materials, processes, etc., and which
are considered subject to the same failure. Acceptance of the product shall be discontinued until corrective action,
acceptable to the Government, has been taken. After the corrective action has been taken, group C inspection shall
be repeated on additional sample units (all inspection, or the inspection which the original sample failed, at the option
of the Government). Groups A and B inspections may be reinstituted; however, final acceptance shall be withheld
until the group C reinspection has shown that the corrective action was successful. In the event of failure after
reinspection, information concerning the failure and the corrective action taken shall be furnished to the cognizant
inspection activity and the qualifying activity.
4.7 Periodic group C inspection.
4.7.1 Visual and mechanical examination. Capacitors shall be examined to verify that the materials, design,
construction, physical dimensions, marking, and workmanship are in accordance with the applicable requirements
(see 3.1, 3.3, 3.5, 3.26, and 3.27).
CAUTION: CARE SHOULD BE USED IN OPENING AND HANDLING THESE CAPACITORS DURING
THE INTERNAL EXAMINATION SINCE SOME OF THE ELECTROLYTES USED ARE DANGEROUS AND
MAY CAUSE HARM TO PERSON OR PROPERTY.
4.7.2 Seal (see 3.6). Capacitors shall be tested in accordance with method 112 of MIL-STD-202. When
applicable, this test may be performed prior to the addition of the sleeving. The following details shall apply:
a.
Test condition - A or D.
b.
Measurement after test - Not applicable.
4.7.3 Dielectric withstanding voltage (styles CL55 and insulated styles only see 3.1) (see 3.7). Capacitors shall be
tested in accordance with method 301 of MIL-STD-202 as specified in 4.7.3.1 or 4.7.3.2.