MIL-PRF-55365H
APPENDIX A
A.3.1.3 Combined-voltage submission (Weibull). Three hundred sample units of the highest capacitance value of
the lowest voltage and 300 sample units of the highest capacitance value of the highest voltage in each voltage group
for each style for which qualification is sought shall be submitted (see table A-I). Weibull FRL grading shall be
performed in accordance with 3.23 and 4.7.20 instead of voltage aging (exponential only) in group I of table VI. DC
leakage, capacitance, dissipation factor, and ESR (when specified, see 3.1) shall be performed only once. All other
exponential tests in table VI shall not apply.
A.3.1.4 Styles CWR09, CWR19 and CWR29. Qualifying to CWR29 will extend qualification to styles CWR09 and
CWR19.
A.4 EXTENT OF QUALIFICATION
A.4.1 Single-style submission. Capacitance-range qualification will be restricted to values equal to or less than the
capacitance value submitted. Capacitance-tolerance qualification will be restricted to tolerances equal to and wider
than the tolerance submitted. Voltage rating qualification shall be restricted to those submitted.
A.4.2 Combined voltage submission. Capacitance range qualification will be restricted to values equal to or less
than the capacitance value submitted. Capacitance tolerance qualification will be restricted to tolerances equal to
and wider than the tolerance submitted. Voltage rating qualification shall be restricted to those submitted.
A.4.3 Weibull qualification via similarity. Capacitance range qualification will be restricted to values equal to or
less than the capacitance value submitted. Capacitance tolerance qualification will be restricted to tolerances equal
to and wider than the tolerance submitted. Voltage rating qualification shall be restricted to those submitted.
A.4.4 Non-ER capacitors (A level). Qualification of the A (non-ER) level is predicated upon meeting the
qualification requirements for the established reliability FRL B.
NOTE: Since the non-ER (A level) is the ER design without the mandatory conformance inspection and FRL
assessment, the product is still expected to meet the environmental qualification type requirements (e.g., moisture
resistance, or thermal shock.).
NOTE: "T" level qualification requires that the manufacturer is qualified to weibull grade C or D of equivalent part.