MIL-PRF-55365H
APPENDIX A
PROCEDURES FOR QUALIFICATION INSPECTION
A.1 SCOPE
A.1.1 Scope. This appendix details the procedures for submission of samples for qualification inspection of
capacitors covered by this specification. The procedures for extending qualification of the required sample to other
capacitors covered by this specification are also obtained herein. This appendix is a mandatory part of this
specification. The information contained herein is intended for compliance.
A.2 APPLICABLE DOCUMENTS. This section is not applicable to this appendix.
A.3 SUBMISSION
A.3.1 Sample.
A.3.1.1 Single-style submission. A sample of the size required in table VI, of the highest capacitance value in
each voltage rating in each style for which qualification is sought, shall be submitted.
A.3.1.2 Combined-voltage submission (exponential). Samples shall be submitted in accordance with table A-I for
each style for which qualification is sought. Each voltage group (see 4.6.1.1.1), 4 - 20 volts and 25 to 50 volts are
qualified separately. The break down is the highest capacitance value in the smallest and largest case size, and
lowest voltage and highest voltage.
39
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business