MIL-PRF-39006/21C
ĆCap.: Within +10 percent to -25 percent of initial measurement for 6-volt units;
within +10 percent to -20 percent of initial measurement for 8- and 10- volt units;
within +10 percent to -15 percent of initial measurement for 15-volt units; and
within ± 10 percent of initial measurement for all other units.
DF: See table I.
10,000 hours (group B) and extended life:
DCL (85°C): 125 percent (max) of table I value.
DCL (25°C): See table I.
ĆCap.: Within +10 percent, -60 percent of initial measurement.
DF: 200 percent (max) of table I value.
DWV: 2,000 V dc, minimum.
IR.: 100 megohms, minimum.
Vacuum life:
DCL: See table I.
ĆCap.: Within ±20 percent of initial measurement.
DF: See table I.
Weight loss: 4.1 mg, maximum.
Life at 125°C: Method 108 of MIL-STD-202.
DCL: See table I.
ĆCap.: Within +10 percent to -25 percent of initial measurement for 6-volt units;
within +10 percent to -20 percent of initial measurement for 8- and 10- volt units;
within +10 percent to -15 percent of initial measurement for 15-volt units; and
within ± 10 percent of initial measurement for all other units.
DF: See table I.
DWV: 2,000 V dc, minimum.
IR.: 100 megohms, minimum.
2,000 hours (group C):
DCL (125°C): 125 percent (max) of table I value.
DCL (25°C): See table I.
ĆCap.: Within +10 percent, -60 percent of initial measurement.
DF: 200 percent (max) of table I value.
9
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business