MIL-PRF-39006/21C
Stability at low and high temperatures:
Step 1 (+25°C):
DCL: See table I.
ĆCap.: Within tolerance of table I value.
DF: See table I.
Step 2 (-55°C):
Imp. See table I.
ĆCap.: See table I.
Step 3 (+25°C):
DCL: See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF: See table I.
Step 4 (+85°C):
DCL: See table I.
ĆCap.: See table I.
DF: See table I.
Step 5 (+125°C):
DCL: See table I.
ĆCap.: See table I.
DF: See table I.
Step 6 (+25°C):
DCL: See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF: See table I.
Reverse voltage: Not applicable.
Life at 85°C: Method 108 of MIL-STD-202.
2,000 hours (qualification):
DCL: See table I.
8