MIL-PRF-39006/21C
Constant voltage conditioning: As specified in MIL-PRF-39006.
DC leakage (DCL) (max) (at 25°C): See table I.
Dissipation factor (DF) (max): See table I.
Seal: Method 112 of MIL-STD-202, conditions A and C.
Shock (specified pulse): Method 213 of MIL-STD-202, condition I (100 G).
Vibration, high frequency: Method 204 of MIL-STD-202, condition D (20 G).
Thermal shock: Method 107 of MIL-STD-202, condition A (with step 3 at +125°C). Number of cycles = 30.
DCL: 125 percent (max) of 25°C value of table I.
ĆCap.: Within ±5 percent of initial measurement.
DF: 115 percent (max) of initial requirement.
Salt spray (corrosion): Method 101 of MIL-STD-202, condition B (48 hours).
Solderability: Method 208 of MIL-STD-202.
Terminal strength:
Pull: Method 211 of MIL-STD-202, condition A.
Wire-lead bend: In accordance with MIL-PRF-39006.
Surge voltage: See table I.
Moisture resistance: Method 106 of MIL-STD-202.
DCL: 125 percent (max) of 25°C value of table I.
ĆCap.: Within ±8 percent of initial measurement.
DF: 115 percent (max) of initial requirement.
Dielectric withstanding voltage (DWV): Method 301 of MIL-STD-202. 2,000 V dc, minimum.
Insulation resistance (IR): Method 302 of MIL-STD-202, condition B. 100, megohms, minimum.
Low temperature (storage): Method 502 of MIL-STD-810.
DCL: See table I.
ĆCap.: Within ±5 percent of initial measurement.
DF: See table I.