TABLE I. Capacitor characteristics - Continued.
Rated
Dissi-
PIN M39006/21-
voltage
pation
Cap.
Cap.
DC leakage
Derated Surge
Imped-
Capacitance
(+85°C)
Case
toler-
(max)
voltage voltage
ance
change at
factor
Failure rate level (%/1,000 hour)
(+125°C) (+85°C)
+25°C +85°C &
-55°C
+85°C +125°C
size
ance
(max)
(max)
+125°C
M
P
R
S
L
µF
percent
percent volts, dc volts, dc
ohms
µA
volts, dc
µA
(1.0)
(0.1)
(0.01)
(0.001)
(2.0)
percent
percent
percent
±20
25
560
7
28
76
15
28.8
24
-72
+20
+25
T3
0037
0125
0213
0301
0389
±10
25
560
7
28
76
15
28.8
24
-72
+20
+25
T3
0038
0126
0214
0302
0390
±20
25
680
8
32
63
15
28.8
19
-72
+25
+30
T4
0039
0127
0215
0303
0391
±10
25
680
8
32
63
15
28.8
19
-72
+25
+30
T4
0040
0128
0216
0304
0392
±20
30
56
2
9
22
20
34.5
100
-38
+12
+15
T1
0041
0129
0217
0305
0393
±10
30
56
2
9
22
20
34.5
100
-38
+12
+15
T1
0042
0130
0218
0306
0394
±20
30
220
3
16
42
20
34.5
36
-60
+13
+16
T2
0043
0131
0219
0307
0395
±10
30
220
3
16
42
20
34.5
36
-60
+13
+16
T2
0044
0132
0220
0308
0396
±20
30
470
8
32
64
20
34.5
25
-65
+20
+25
T3
0045
0133
0221
0309
0397
±10
30
470
8
32
64
20
34.5
25
-65
+20
+25
T3
0046
0134
0222
0310
0398
±20
30
560
9
36
55
20
34.5
20
-65
+25
+30
T4
0047
0135
0223
0311
0399
±10
30
560
9
36
55
20
34.5
20
-65
+25
+30
T4
0048
0136
0224
0312
0400
±20
50
33
2
9
12.3
30
57.5
135
-29
+10
+12
T1
0049
0137
0225
0313
0401
±10
50
33
2
9
12.3
30
57.5
135
-29
+10
+12
T1
0050
0138
0226
0314
0402
±20
50
120
4
24
22.5
30
57.5
49
-42
+12
+15
T2
0051
0139
0227
0315
0403
±10
50
120
4
24
22.5
30
57.5
49
-42
+12
+15
T2
0052
0140
0228
0316
0404
±20
50
270
8
32
37
30
57.5
29
-46
+20
+25
T3
0053
0141
0229
0317
0405
±10
50
270
8
32
37
30
57.5
29
-46
+20
+25
T3
0054
0142
0230
0318
0406
±20
50
330
9
36
38
30
57.5
22
-46
+25
+30
T4
0055
0143
0231
0319
0407
±10
50
330
9
36
38
30
57.5
22
-46
+25
+30
T4
0056
0144
0232
0320
0408
±20
60
27
3
12
10.2
40
69.0
144
-24
+10
+12
T1
0057
0145
0233
0321
0409
±10
60
27
3
12
10.2
40
69.0
144
-24
+10
+12
T1
0058
0146
0234
0322
0410
±20
60
100
4
20
19
40
69.0
54
-36
+12
+15
T2
0059
0147
0235
0323
0411
±10
60
100
4
20
19
40
69.0
54
-36
+12
+15
T2
0060
0148
0236
0324
0412
±20
60
220
8
32
30
40
69.0
29
-40
+16
+20
T3
0061
0149
0237
0325
0413
±10
60
220
8
32
30
40
69.0
29
-40
+16
+20
T3
0062
0150
0238
0326
0414
±20
60
270
9
36
27
40
69.0
23
-45
+20
+25
T4
0063
0151
0239
0327
0415
±10
60
270
9
36
27
40
69.0
23
-45
+20
+25
T4
0064
0152
0240
0328
0416
±20
75
22
3
12
8.5
50
86.2
157
-19
+10
+12
T1
0065
0153
0241
0329
0417
±10
75
22
3
12
8.5
50
86.2
157
-19
+10
+12
T1
0066
0154
0242
0330
0418
±20
75
82
4
24
15.2
50
86.2
63
-30
+12
+15
T2
0067
0155
0243
0331
0419
±10
75
82
4
24
15.2
50
86.2
63
-30
+12
+15
T2
0068
0156
0244
0332
0420
±20
75
180
9
36
24.4
50
86.2
30
-35
+16
+20
T3
0069
0157
0245
0333
0421
±10
75
180
9
36
24.4
50
86.2
30
-35
+16
+20
T3
0070
0158
0246
0334
0422
±20
75
220
10
40
37.0
50
86.2
24
-40
+20
+25
T4
0071
0159
0247
0335
0423
±10
75
220
10
40
37.0
50
86.2
24
-40
+20
+25
T4
0072
0160
0248
0336
0424