MIL-PRF-83500A
Step 1 (+25°C):
DC leakage------------------------ Shall not exceed the initial requirement (see 3.6).
Capacitance ---------------------- Shall be within the applicable tolerance specified (see 3.1).
Dissipation factor---------------- Shall not exceed the initial requirement (see 3.8).
Step 2 (-55°C):
Impedance ------------------------ Shall not exceed the applicable value specified (see 3.1).
Capacitance ---------------------- Shall change not more than the percent specified (see 3.1) from the step 1
measured value.
Step 3 (+25°C):
DC leakage------------------------ Shall not exceed the initial requirement (see 3.6).
Capacitance----------------------- Shall change not more than ±5 percent from the step 1 measured value.
Dissipation factor----------------- Shall not exceed the initial requirement (see 3.8).
Step 4 (+85°C):
DC leakage------------------------ Shall not exceed the applicable value specified (see 3.1).
Capacitance ---------------------- Shall change not more than the percent specified (see 3.1) from the step 1
measured value.
Dissipation factor---------------- Shall not exceed the applicable value specified (see 3.1).
Step 5 (+125°C):
DC leakage------------------------ Shall not exceed the applicable value specified (see 3.1).
Capacitance ---------------------- Shall change not more than the percent specified (see 3.1) from the step 1
measured value.
Dissipation factor---------------- Shall not exceed the applicable value specified (see 3.1).
Step 6 (+25°C):
DC leakage------------------------ Shall not exceed the initial requirement (see 3.6).
Capacitance ---------------------- Shall change not more than ±5 percent from the step 1 measured value.
Dissipation factor---------------- Shall not exceed the initial requirement (see 3.8).
3.20 Barometric pressure (reduced). When capacitors are tested as specified in 4.6.17, there shall be no
flashover, breakdown, or harmful deformation of the case, and no mechanical damage, obliteration of marking, or
leakage of electrolyte.
3.21 Reverse voltage (applicable to polarized capacitors only, see 3.1). When tested as specified in 4.6.18,
capacitors shall meet the following requirements:
DC leakage------------------------ Shall not exceed 125 percent of the initial requirement (see 3.6).
Capacitance ---------------------- Shall change not more than ±10 percent from the initial measured value
(see 3.7).
Dissipation factor---------------- Shall not exceed the initial requirement (see 3.8).
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business