MIL-PRF-39022/10B
Barometric pressure (reduced): Method 105 of MIL-STD-202, condition D (100,000 feet). 125 percent of rated
voltage applied. See MIL-PRF-39022 for voltage limitations.
Vibration, high frequency: Method 204 of MIL-STD-202, condition D (20 G).
50 percent of rated voltage applied.
Salt atmosphere (corrosion): Method 101 of MIL-STD-202, condition B (48 hours).
Salt solution: 5 percent.
Immersion: Method 104 of MIL-STD-202, condition C.
DWV:
Insulating sleeves: 4,000 V dc, minimum.
Terminal to terminal: 150 percent of rated voltage.
Terminals to case (when case is not a terminal): 200 percent of dc rated voltage.
IR:
Insulating sleeves: 100 megohms, minimum.
Terminal to terminal: 60 percent of value specified in table III.
Terminals to case (when case is not a terminal): 30,000 megohms, minimum.
Capacitance: Within ±3 percent of initial value.
DF: Not more than 110 percent of initial limit.
Solderability: Method 208 of MIL-STD-202.
Shock (specified pulse): Method 213 of MIL-STD-202, condition I.
50 percent of rated voltage applied.
Resistance to soldering heat: Method 210 of MIL-STD-202, condition C, except the time shall be 10 seconds
± 1 second.
IR: See table III.
Capacitance: Within ± 3 percent of initial value.
DF: Not more than initial limit.
Moisture resistance: Method 106 of MIL-STD-202.
DWV, IR, Capacitance, and DF: Same as for immersion.
Terminal strength: Method 211 of MIL-STD-202, conditions A and D.
Condition A: Applied force 5 pounds.
Condition D: 3 rotations of 360 degrees.