MIL-PRF-19978K
TABLE IX. Qualification inspection.
NON-ER
ER
Number
Number
Number of
Number of
Requirement
Method
of sample
of sample
Inspection
defectives
defectives
paragraph
Paragraph
units
units
allowed
allowed
to be
to be
1/
1/
inspected
inspected
Group I
Visual and mechanical examination
(internal):
0
2
0
2
Material and workmanship
Group II
Visual and mechanical examination
(external):
Physical dimensions, marking, and
workmanship 2/
Thermal shock 3/
Radiographic inspection (ER only, when
applicable) 3/
43
1
80
0
Burnin (ER only, when applicable) 3/
Seal
Dielectric withstanding voltage 3/
Barometric pressure (reduced)
(when applicable) 3/
Insulation resistance 3/
Capacitance 3/
Dissipation factor 3/
Group III
Vibration
1
12
1
6
Salt spray (corrosion) (metal case only)
Immersion
Group IV
Solderability (wire leads only)
6
1
6
1
1
Group V
1
Shock (specified pulse)
1
12
1
6
Terminal strength
Moisture resistance
Group VI
Dielectric absorption (when specified)
1
40
1
24
Stability at low and high temperatures 3/
Temperature coefficient (characteristic P)
Life
Group VII
Fungus
5
1
10
N/A
N/A
Resistance to solvents
Resistance to soldering heat (wire lead only)
5
Moisture resistance
Group VIII
Flashpoint of impregnant or filling compound
2 4/
N/A
2 4/
N/A
1/ A sample unit having one or more defects will be considered as a single defective.
2/ Marking defects are based on visual examination only and will be charged only for illegible, incomplete, or
incorrect marking.
3/ Nondestructive tests.
4/ Two samples shall be taken from the quarter-pound impregnant or filling compound submitted.
13
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business