MIL-PRF-19978K
TABLE XIV. Group B inspection
Number of defectives
Requirement
Method
Number of
allowed
Inspection
paragraph
paragraph
samples
Non-ER
ER
Subgroup 1
Shock (specified pulse) 1/ 2/
1
1
12
Vibration 2/
Salt spray (corrosion) (metal cases only) 3/
Immersion 3/
1
1
Subgroup 2
Terminal strength 3/
1
1
12
Moisture resistance 3/
Dielectric withstanding voltage (sleeving
only) 3/
Subgroup 3
Life
12 (Non-ER)
see 4.6.3.1
1
ER (10 per
inspection lot
minimum)
Subgroup 4
Insulation resistance (at high ambient
Test temperature)
Dielectric absorption (when specified)
1
1
12
Stability at low and high temperatures
Temperature coefficient (characteristic P
only)
Subgroup 5
1
N/A
6
Resistance to solvents 3/
Resistance to soldering heat (wire-lead
styles only) 3/
1/ Not applicable to ceramic or glass-cased units
2/ The time period for shock and vibration tests is a minimum of once every 24 months.
3/ If the manufacturer can demonstrate that this test has been performed five consecutive times with zero failures,
this test, with the approval of the qualifying activity, can be deleted. The manufacturer, however, shall perform
this test every three years after the deletion as part of long term design verification. If the design, material,
construction, or processing of the part is changed, or if there are any quality problems, the qualifying activity may
require resumption of the specified testing. Deletion of testing does not relieve the manufacturer from meeting
the test requirements in case of dispute.
4.7 Methods of examination and test.
4.7.1 Visual and mechanical examination. Capacitors and retainers shall be examined to verify that the materials,
design, construction, physical dimensions, marking, and workmanship are in accordance with the applicable
4.7.2 Burn-in (see 3.6) (ERs only, when applicable. see 3.1). Capacitors shall be subjected to 140 percent,
minimum, of the dc rated voltage at the high ambient test temperature for 48 hours +8 hours, -0 hours. During this
test, capacitors shall be adequately protected against temporary voltage surges of 10 percent or more of the test
voltage. After the test, capacitors shall show no evidence of damage, arcing, or breakdown.
19