MIL-C-62F
TABLE IV. Qualification inspection.
Examination or test
Requirement
Method
Number of
Number of
paragraph
paragraph
sample units
defectives
allowed 1/
to be
inspected
Group I
Visual and mechanical examination
(internal)
---
4.5.1 and
2
0
Material, design, construction,
and workmanship
incl, 3.23, and
Solderability (not applicable to
plug-in capacitors and styles
CE70 and CE71)
6
0
Visual and mechanical examination
---
(external) 2/
Physical dimensions, marking, 3/
and workmanship
incl, and 3.22 to
3.23.1 incl
1
43 4/
31 4/
DC leakage 2/
Capacitance 2/
Dissipation factor 2/
Terminal strength (not applicable to
plug-in capacitors) 2/
Group II
Shock (specified pulse)
Vibration
4.5.8 to
2
4.5.8.2 incl
Salt atmosphere
6
1
Temperature cycling and immersion
4.5.10 to
4.5.10.2 incl
Group III
Moisture resistance
4.5.11
6
1
Group IV
Stability at low and high
temperatures 2/
Surge voltage
6
1
Vent (applicable only to styles
CE70 and CE71)
Group V
18 5/
Life
1
Group VI
Barometric pressure
4.5.18 and
Shelf life
1
6
1/ A sample unit having one or more defects shall be considered as a single defective.
2/ Nondestructive tests.
3/ Marking shall be considered as a defect only if it becomes illegible as a result of any of the
inspections.
4/ One additional sample unit is included in each sample of 43 (or 31, as applicable) sample units to
permit substitution for the allowable defect in group I.
5/ Six sample units to be inspected for styles CE63 and CE64 capacitors.
10