MIL-C-11272E
1.2.1.4 Capacitance tolerance. The capacitance tolerance is identified by a single letter in accordance with
table II.
TABLE II. Capacitance tolerance.
Capacitance
tolerance (±)
Symbol
B
0.10 pF
C
0.25 pF
D
0.50 pF
F
1%
G
2%
J
5%
K
10%
M
20%
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This
section does not include documents cited in other sections of this specification or recommended for additional
information or as examples. While every effort has been made to ensure the completeness of this list, document
users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this
specification, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a
part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are
those cited in the solicitation or contract (see 6.2).
*
DEPARTMENT OF DEFENSE SPECIFICATIONS
-
Capacitors, Fixed, Glass Dielectric, Style CY10
-
Capacitors, Fixed, Glass Dielectric, Style CY15
-
Capacitors, Fixed, Glass Dielectric, Style CY06
-
Capacitors, Fixed, Glass Dielectric, Style CY07
-
Capacitors, Fixed, Glass Dielectric, Style CY08
-
Capacitors, Fixed, Glass Dielectric, Established Reliability, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
-
Test Method Standard for Electronic and Electrical Component Parts.
-
Leads for Electronic Component Parts.
*
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the
Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.3 Non-Government publications. The following documents form a part of this document to the extent specified
herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
-
Calibration Laboratories and Measuring and Test Equipment - General
Requirements (Replaces MIL-STD-45662.)
(Copies of this document may be ordered online at www.ncsli.org or from NCSL International, 1800 30th Street,
Suite 305, Boulder, CO 80701-1026)
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business