MIL-C-11015/19E
REQUIREMENTS:
Design and construction:
Dimensions and configuration: See figure 1.
Case type - Flat plate, molded or pre-formed.
Capacitance value - See table I.
Capacitance tolerance -
10 percent (K) or 20 percent (M) as shown in table I.
Rated temperature - -55 C to +125 C
(although 1,200 pF through 10,000 pF capacitors are identified as B units, they shall have the
capability of -55 C to +150 C operation, see figure 2.)
Dielectric withstanding voltage (DWV): In accordance with MIL-C-11015.
Dielectric:
Test voltage - 250 percent of rated voltage.
Body insulation:
Test potential - 1,300 volts dc.
Barometric pressure (reduced): In accordance with MIL-C-11015 and method 105 of MIL-STD-202, test condition
D (100,000 ft) (0.315 inch (8.00 mm) of mercury).
Test potential - 150 percent of rated voltage.
Insulation resistance (IR): In accordance with MIL-C-11015; rated voltage applied.
100,000 megohms, min or 1,000 megohm-microfarads, min, whichever is less.
Dissipation factor (DF): 2.5 percent, max.
Shock (specified pulse): In accordance with MIL-C-11015 and method 213 of MIL-STD-202, condition I (100 G's).
Vibration, high frequency: In accordance with MIL-C-11015 and method 204 of MIL-STD-202, condition D
(20 g's).
Thermal shock and immersion: In accordance with MIL-C-11015.
IR - Not less than 50 percent of initial 25 C requirement.
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business