MIL-PRF-39014/5G
Life:
Rated conditions - 100 percent of dc rated voltage at 125°C.
0 hours through 3,000 hours:
At 25°C, not less than 50 percent of initial 25°C requirement.
IR
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC
±20 percent from initial measured value.
DF
Not greater than 2.5 percent for BX; not more than 3.0 percent for BR.
4,000 hours through 32,000 hours:
At 25°C, not less than 15 percent of initial 25°C requirement
IR
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC
±20 percent from initial measured value.
DF
Not greater than 2.5 percent for BX; not more than 3.0 percent for BR.
Accelerated conditions - 200 percent of dc rated voltage at 125°C.
0 hours and 250 hours:
At 25°C, not less than 50 percent of initial 25°C requirement.
IR
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC
±20 percent from initial measured value.
DF
Not greater than 2.5 percent for BX; not more than 3.0 percent for BR.
1,000 hours, 2,000 hours, and 4,000 hours:
At 25°C, not less than 15 percent of initial 25°C requirement.
IR
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC
±20 percent from initial measured value.
DF
Not greater than 2.5 percent for BX; not more than 3.0 percent for BR.
Part or Identifying Number (PIN): M39014/05-(dash number from table I).