MIL-PRF-39014/1H
Immersion:
IR: Not less than 50 percent of initial 25°C requirement.
*
Salt atmosphere (corrosion) (salt spray): Not applicable.
Life:
Rated conditions, 100 percent of dc rated voltage at 125°C.
0 hour through 3,000 hours:
IR: At 25°C, not less than 50 percent of initial 25°C requirement.
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
4,000 hours through 32,000 hours:
IR: At 25°C, not less than 15 percent of initial 25°C requirement.
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
Accelerated conditions, 200 percent of dc rated voltage at 125°C.
0 hour and 250 hours:
IR: At 25°C, not less than 50 percent of initial 25°C requirement.
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
1,000 hours, 2,000 hours, and 4,000 hours:
IR: At 25°C, not less than 15 percent of initial 25°C requirement.
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
*
Resistance to soldering heat: Resistance to soldering heat shall be in accordance with method 210 of MIL-STD-
202, test condition C.
ĆC: +15 percent, -5 percent of the initial 25°C measurement.
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.