MIL-C-39022/9D
TABLE II. Measurement values.
CHR01C, CHR01F,
CHR01B, CHR01E,
CHR01A, CHR01D,
CHR01J, CHR01M,
CHR01H, CHR01L,
Measurement
CHR01G, CHR01K,
and CHR01R
and CHNR01P
and CHR01N
Insulation resistance (terminal to terminal)
Megohms x microfarads (min):
At +25°C - - - - - - - - - - - - - - - - - - - - -
300,000
200,000
100,000
At +100°C - - - - - - - - - - - - - - - - - - - -
30,000
20,000
5,000
At +125°C - - - - - - - - - - - - - - - - - - - -
2,000
1,000
1,000
Megohms (need not exceed):
3,000,000
2,000,000
1,000,000
At +25°C - - - - - - - - - - - - - - - - - - - - -
300,000
200,000
50,000
At +100°C - - - - - - - - - - - - - - - - - - - -
20,000
10,000
10,000
At +125°C - - - - - - - - - - - - - - - - - - - -
Capacitance change with temp (max)
At -55°C - - - - - - - - - - - - - - - - - - - - -
-2.5% to 0%
-2.5% to 0%
-2.5% to 0%
±.25%
±.25%
±.25%
At +25 (retrace) - - - - - - - - - - - - - - - -
At +125°C - - - - - - - - - - - - - - - - - - - -
±2.0%
-1.0% to+1.2%
-1.0% to+1.2%
Dissipation factor (max) - - - - - - - - - - - - - -
0.15%
0.2%
0.25%
Flash point of impregnant: Not applicable.
Radiographic inspection (X-ray): Not applicable.
Thermal shock: Method 107 of MIL-STD-202, condition B.
Seal: Method 112 of MIL-STD-202, test condition C, procedure IIIA; no evidence of leakage with the exception of
the following:
R1
2
Exposure time
Maximum dwell
Styles
Reject limit
lbf/in
3
hours
hours
(atm cm /s)
CHR01A, CHR01B, CHR01D,
-6
45 ± 5
1 +1-0
1
CHR01E, CHR01G, CHR01H,
1 x 10
CHR01K, CHR01L, CHR01N,
and CHR01P
-5
45 ± 5
CHR01C, CHR01F, CHR01J,
1 +1-0
1
1 x 10
CHR01M, and CHR01R
Dielectric withstanding voltage (DWV): Method 301 of MIL-STD-202; no momentary breakdown:
Terminal to terminal:
AC: 100 ± 10 Hz square wave, peak-to-peak voltage, three times dc rated voltage for 60 seconds,
minimum. Need not exceed 800 peak-to-peak.
DC: 200 percent of dc rated voltage for 60 seconds, min.
11