MIL-PRF-55365/8J
TABLE I. Style CWR11 characteristics - Continued.
DC Leakage
Dissipation factor
Max
Part or
DC rated
(max)
(max)
ESR 100 Case
identifying number
Cap.
voltage
+85°C
kHz
(PIN)
(nom)
size
(+85°C)
+25°C
+85°C
+125°C
+25°C
-55°C
+25°C
+125°C
1/
µF
µA
µA
µA
Volts
%
%
%
Ohms
CWR11K-334 - - -
25
0.33
0.5
5.0
6.0
4
6
6
15.0
A
CWR11K-474 - - -
25
0.47
0.5
5.0
6.0
4
6
6
14.0
A
CWR11K-684 - - -
25
0.68
0.5
5.0
6.0
4
6
6
7.5
B
CWR11K-105 - - -
25
1.0
0.5
5.0
6.0
4
6
6
6.5
B
CWR11K-155 - - -
25
1.5
0.5
5.0
6.0
6
8
9
6.5
B
CWR11K-225 - - -
25
2.2
0.6
6.0
7.2
6
9
9
3.5
C
CWR11K-335 - - -
25
3.3
0.9
9.0
10.8
6
8
9
3.5
C
CWR11K-475 - - -
25
4.7
1.2
12.0
14.4
6
9
9
2.5
C
CWR11K-685 - - -
25
6.8
1.7
17.0
20.4
6
9
9
1.4
D
CWR11K-106 - - -
25
10.0
2.5
25.0
30.0
6
8
9
1.2
D
CWR11K-156 - - -
25
15.0
3.8
38.0
45.6
6
9
9
1.0
D
CWR11M-104 - - -
35
0.10
0.5
5.0
6.0
4
6
6
24.0
A
CWR11M-154 - - -
35
0.15
0.5
5.0
6.0
4
6
6
21.0
A
CWR11M-224 - - -
35
.22
0.5
5.0
6.0
4
6
6
18.0
A
CWR11M-334 - - -
35
.33
0.5
5.0
6.0
4
6
6
15.0
A
CWR11M-474 - - -
35
.47
0.5
5.0
6.0
4
6
6
10.0
B
CWR11M-684 - - -
35
.68
0.5
5.0
6.0
4
6
6
8.0
B
CWR11M-105 - - -
35
1.0
0.5
5.0
6.0
4
6
6
6.5
B
CWR11M-155 - - -
35
1.5
0.5
5.0
6.0
6
8
9
4.5
C
CWR11M-225 - - -
35
2.2
0.8
8.0
9.6
6
8
9
3.5
C
CWR11M-335 - - -
35
3.3
1.2
12.0
14.4
6
8
9
2.5
C
CWR11M-475 - - -
35
4.7
1.7
17.0
20.4
6
8
9
1.5
D
CWR11M-685 - - -
35
6.8
2.4
24.0
28.8
6
9
9
1.3
D
CWR11N-104 - - -
50
.10
0.5
5.0
12
6
8
8
22.0
A
CWR11N-154 - - -
50
.15
0.5
5.0
6.0
4
6
6
17.0
B
CWR11N-224 - - -
50
.22
0.5
5.0
6.0
4
6
6
14.0
B
CWR11N-334 - - -
50
.33
0.5
5.0
6.0
4
6
6
12.0
B
CWR11N-474 - - -
50
.47
0.5
5.0
6.0
4
6
6
8.0
C
CWR11N-684 - - -
50
.68
0.5
5.0
6.0
4
6
6
7.0
C
CWR11N-105 - - -
50
1.0
0.5
5.0
6.0
4
6
6
6.0
C
CWR11N-155 - - -
50
1.5
0.8
8.0
9.6
6
8
9
4.0
D
CWR11N-225 - - -
50
2.2
1.1
11.0
13.2
6
8
9
2.5
D
CWR11N-335 - - -
50
3.3
1.7
17.0
20.4
6
9
9
2.0
D
CWR11N-475 - - -
50
4.7
2.4
24.0
28.8
6
9
9
1.5
D
1/ Complete PIN shall include additional symbols to indicate termination finish, capacitance tolerance, product