MIL-PRF-39018/7C
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Case:
Type: Tubular.
Material: Metal.
Leads: See figure 1.
DC rated voltage: See table I.
Reverse voltage: 1.5 volts maximum.
Capacitance (Cap.) value: See table I.
Cap. tolerance: -10, +75 percent.
Failure rate level: M, P, R, and S.
Operating temperature range: -55°C to +105°C.
Burn-in: In accordance with MIL-PRF-39018.
DC leakage (DCL), See table I.
Equivalent Series Resistance (ESR): See table I.
Low temperature exposure:
DCL - See table I.
Cap. - See table I.
ESR - See table I.
Terminal strength: Method 211 of MIL-STD-202, test conditions A (3 pounds) and D (3 rotations).
Solderability: In accordance with MIL-PRF-39018.
Stability at reduced and high temperatures:
Step 1 (at +25°C):
DCL - See table I.
Cap. - See table I.
ESR - See table I.
Step 2 (at -55°C):
Impedance - See table I.
ĆCap. - Within the following percentages of the step 1 value:
5 to 40 V dc inclusive: ±25 percent.
50 to 100 V dc inclusive: ±20 percent.
150 to 200 V dc inclusive: ±30 percent.
Step 3 (at +25°C):
DCL - See table I.
ĆCap. - Within ±5 percent of step 1 value.
ESR - See table I.