MIL-PRF-39018/1H
Moisture resistance: Method 106 of MIL-STD-202.
DCL: See table I.
ĆCap: Within ±6 percent of initial measured value.
ESR: See table I.
Case Insulation (CU13 and CUR13 only): Shall meet initial requirement.
High temperature exposure (500 hours at +125°C):
DCL: Not more than 200 percent of initial requirement for units less than 150 volts and 300 percent for units
150 volts and greater.
ĆCap.: Within ±10 percent of initial measured value.
ESR: Not more than 115 percent of initial requirement.
Reverse voltage:
After 125 hours at 125°C with 1 +0 -.1 reverse volt applied to units rated at 7 V dc, and 3 +0 -.3 reverse volts
applied to all others.
After additional 125 hours at 125°C with rated forward voltage applied:
DCL: Within 125 percent of initial requirement.
ĆCap.: Within the following percentages of the initial measured value:
7 to 30 V dc inclusive: +10, -25 percent.
50 to 350 V dc inclusive: ±10 percent.
ESR: See table I.
Penetration of solvents: In accordance with MIL-PRF-39018.
High temperature verification: In accordance with MIL-PRF-39018 at +125°C with derated voltage applied:
DCL: See table I.
ĆCap: Within 10 percent of initial measured value.
ESR: Not more than 130 percent of initial requirement.
Reverse voltage aging: In accordance with MIL-PRF-39018.
Marking: In accordance with MIL-PRF-39018.
Part or Identifying Number (PIN): M39018/01- (Dash number from table I). For style CUR13, parts with random
vibration, the letter R shall be used in place of the dash (i.e., M39018/01R1046M).
Substitutability data: See table II.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business