MIL-PRF-39018/1H
For quality conformance: Performance check, condition B (250 hours) at +85°C (non-ER).
DCL: See table I.
ĆCap.: Within ±10 percent of initial measured value.
ESR: See table I.
For quality conformance: Continuation test (1,750 hours) at +85°C (non-ER).
DCL: See table I.
ĆCap.: Within ±15 percent of initial measured value.
ESR: Not more than 130 percent of initial requirement.
For quality conformance: 10,000 hours (ER) at +85°C.
DCL: At +25°C initial limit, at +85°C, 125 percent of initial limit.
ĆCap.: Within ±25 percent of initial measured value.
ESR: Not more than 200 percent of initial requirement.
Case insulation (CU13 and CUR13 only): In accordance with MIL-PRF-39018.
Vibration:
*
High frequency: In accordance with MIL-PRF-39018.
Random (style CUR13 only) (when applicable): In accordance with MIL-PRF-39018.
Thermal shock and immersion:
Thermal shock: Method 107 of MIL-STD-202, condition A, except in step 3, units shall be tested at applicable
high temperature.
Immersion: Method 104 of MIL-STD-202, condition B (2 cycles, 30 minutes).
DCL: See table I.
ĆCap.: Within ±5 percent of initial measured value.
ESR: See table I.
Case insulation (CU13 and CUR13 only): Shall meet initial requirement.
Surge voltage:
DCL: See table I.
ĆCap.: Within ±6 percent of initial measured value.
ESR: See table I.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business