MIL-PRF-39014/20E
Life:
Rated conditions, 100 percent of dc rated voltage at 125°C.
0 through 3,000 hours:
IR: At 25°C, not less than 50 percent of initial 25°C requirement.
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
4,000 through 32,000 hours:
IR: At 25°C, not less than 15 percent of initial 25°C requirement.
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
Accelerated conditions, 200 percent of dc rated voltage at 125°C.
0 and 250 hours:
IR: At 25°C, not less than 50 percent of initial 25°C requirement.
At 125°C, not less than 50 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
1,000, 2,000 and 4,000 hours:
IR: At 25°C, not less than 15 percent of initial 25°C requirement.
At 125°C, not less than 15 percent of initial 125°C requirement.
ĆC: ±20 percent from initial measured value.
Dissipation factor: Not greater than 2.5 percent.
*
Part or identifying number (PIN): M39014/20- (dash number from table I).
3