MIL-PRF-39006/31C
Rated voltage: See table I.
Capacitance (Cap.) nominal (nom): See table I.
Cap. tolerance: ±10 percent or ±20 percent (see table I).
FR level: M, P, R, and S (see table I).
DC leakage (DCL) (max) (at +25°C): See table I.
Cap. (nominal): Method 305 of MIL-STD-202.
Dissipation factor (DF) (max): See table I.
Seal: Method 112 of MIL-STD-202, conditions A or D, and C.
Shock (specified pulse): Method 213 of MIL-STD-202, condition I (100 g's) or condition D (500 g's), as applicable.
Vibration, high frequency: Method 204 of MIL-STD-202, condition D (20 g's) or condition H (80 g's), as applicable.
Random vibration (when applicable): Method 214 of MIL-STD-202, test condition II-K (51 g's).
Thermal shock: Method 107 of MIL-STD-202, condition A (with step 3 at +125°C).
Number of cycles: In accordance with MIL-PRF-39006, the following shall apply.
DCL: 200 percent (max) of +25°C value of table I for qualification and group C.
DCL: 125 percent (max) of +25°C value of table I for group B.
ĆCap: Within ±5 percent of initial measurement.
DF: 115 percent (max) of initial requirement.
Salt spray (corrosion): Method 101 of MIL-STD-202, condition B (48 hours).
Solderability: Method 208 of MIL-STD-202.
Terminal strength:
Pull: Method 211 of MIL-STD-202, condition A.
Wire-lead bend: In accordance with MIL-PRF-39006.
Surge voltage: See table I.
Moisture resistance: Method 106 of MIL-STD-202.
DCL: 125 percent (max) of +25°C value of table I.
ĆCap: Within ±8 percent of initial measurement.
DF: 115 percent (max) of initial requirement.