MIL-PRF-39006/18A
10,000 hours (group B):
DCL (125°C): 125 percent (max) of table I value.
DCL (25°C): See table I.
ĆCap.: Within ±25 percent of initial measurement.
DF: 200 percent (max) of table I value.
DWV and IR: Not applicable.
Barometric pressure: Method 105 of MIL-STD-202, condition E (150,000 feet).
Test voltage: Rated voltage.
Fungus: Method 508 of MIL-STD-810.
Resistance to solvents: Method 215 of MIL-STD-202.
Resistance to soldering heat: Method 210 of MIL-STD-202, condition B.
DCL: See table I.
ĆCap.: Within ±5 percent of initial measurement.
DF: See table I.
Marking: In accordance with MIL-PRF-39006.
Polarity: Series of plus (+) symbols encircling positive end (see figure 1).
Voltage groups (85°C rated voltage):
I - - - - - - - - - - 8 to 90 V inclusive
II - - - - - - - - - - 180 to 360 V inclusive.
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - EC
Air Force - 11
(Project 5910-2158-02)
Review activities:
Navy - AS, MC, OS
Air Force - 19
6