MIL-PRF-39006/18A
Step 5 (+125°C): 1/
DCL: See table I.
ĆCap.: +30 percent (<18 V) or 20 percent (> 18 V) of step 1 value (max).
DF: See table I.
Step 6 (+25°C):
DCL: See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF: See table I.
Reverse voltage: Not applicable.
Life at 85°C: Method 108 of MIL-STD-202.
2,000 hour (qualification):
DCL: See table I.
ĆCap.: Within ±15 percent of initial measurement.
DF: See table I.
10,000 hours (group B) and extended life:
DCL (85°C): 125 percent (max) of table I value.
DCL (25°C): See table I.
ĆCap.: Within ±25 percent of initial measurement.
DF: 200 percent (max) of table I value.
DWV and IR: Not applicable.
Vacuum life: Not applicable.
Life at 125°C: Method 108 of MIL-STD-202.
DCL: See table I.
ĆCap.: Within ±15 percent of initial measurement.
DF: 130 percent (max) of table I value.
DWV and IR: Not applicable.
__________
1/ 125°C derated voltage referenced.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.