MIL-PRF-39006/18A
Moisture resistance: Method 106 of MIL-STD-202.
DCL: 125 percent (max) of 25°C value of table I.
ĆCap.: Within ±8 percent of initial measurement.
DF: 115 percent (max) of table I value.
Dielectric withstanding voltage (DWV): Not applicable.
Insulation resistance (IR): Not applicable.
Low temperature (storage): Method 502 of MIL-STD-810.
DCL: See table I.
ĆCap.: Within ±5 percent of initial measurement.
DF: See table I.
Stability at low and high temperatures:
Step 1 (+25°C):
DCL: See table I.
Cap.: Within tolerance of table I value.
DF: See table I.
Step 2 (-55°C):
Imp. See table I.
ĆCap.: -60 percent (<20 V), -40 percent (30 V), or -30 percent (>30 V) of step 1 value (max).
Step 3 (+25°C):
DCL: See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF: See table I.
Step 4 (+85°C):
DCL: See table I.
ĆCap.: +30 percent (< 20 V) or +20 percent (> 20 V) of step 1 value (max).
DF: See table I.