MIL-PRF-39003/1K
Life: Method 108 of MIL-STD-202:
240, 1,000, and 2,000 hours.
At +25°C (as applicable):
DCL - 200 percent of initial limit.
Capacitance - Not greater than ±5 percent of initial measured value.
DF - See table I.
At +85°C.
DCL - See table I.
At +125°C:
DCL - See table I.
4,000, 6,000, 8,000, and 10,000 hours (exponential only):
At +25°C (as applicable):
DCL - 400 percent of initial limit.
Capacitance - Not greater than ±10 percent of initial measured value.
DF - See table I.
At +85°C:
DCL - 200 percent of initial limit.
At +125°C:
DCL - 200 percent of initial limit.
Marking: In accordance with MIL-PRF-39003.
Part or Identifying Number (PIN): M39003/01- (dash number from table I).
Substitutability data: Substitutability for failure rate levels and capacitance tolerances shall be in accordance with
4