MIL-PRF-39003/1K
Step 1 (+25°C):
DCL - See table I.
Capacitance - Within tolerance of table I value.
DF - See table I.
Step 2 (-55°C):
Capacitance - Not greater than ±10 percent of step 1 measured value.
DF - See table I.
Step 3 (+25°C):
DCL - See table I.
Capacitance - Not greater than ±2 percent of step 1 measured value.
DF - See table I.
Step 4 (+85°C):
DCL - See table I.
Capacitance - Not greater than ±8 percent of step 1 measured value.
DF - See table I.
Step 5 (+125°C):
DCL - See table I.
Capacitance - Not greater than ±12 percent of step 1 measured value.
DF - See table I.
Step 6 (+25°C):
DCL - See table I.
Capacitance - Not greater than ±2 percent of step 1 measured value.
DF - See table I.
Surge voltage: In accordance with MIL-PRF-39003.
DCL - See table I.
Capacitance - Not greater than ±2 percent of initial measured value.
DF - See table I.
3