MIL-PRF-39001/6A
REQUIREMENTS:
Qualification inspection is not required.
Dimensions: See figure 1.
Case: Tubular, molded plastic, encapsulated.
Capacitance value: See table I.
Capacitance tolerance: See table I.
DC rated voltage: 100V, 300V, or 500 V, as shown in table I.
Operating temperature range: -55°C to +125°C.
Characteristic: C, E, or F, See table I.
Failure rate level: M, P, R, and S, see table I.
Barometric pressure: Method 105, condition D (100,000 ft), of MIL-STD-202. Test potential:
150
percent of rated voltage, not to exceed 500 V dc.
Insulation resistance (IR): Method 302, test condition A, of MIL-STD-202: (Minimum requirements):
At 25°C: 100 Gigaohms
At 125°C: 10 Gigaohms
Dissipation factor (DF): See MIL-PRF-39001.
High voltage stabilization: 200 percent of rated dc voltage for 48 hours at a temperature of 125°C
+5°C, -0°C.
Thermal shock and immersion: In accordance with MIL-PRF-39001 except Dcap.
Moisture resistance: In accordance with MIL-PRF-39001 except DCap. shall not exceed ±1.5 percent
of initial measurement or 1pF, whichever is greater.
Life:
Forty eight hours, minimum, at -55°C +0°C -2°C immediately followed by qualification or quality
conformance test, as applicable.
Qualification test: 2,000 hours at +125°C with 100 percent or 150 percent of rated dc voltage
applied, as applicable.
DWV
-
Meet initial requirement.
IR
-
Meet initial requirement.
DCap.
-
Shall not exceed ±1.5 percent of initial measurement or 1 pF, whichever is greater.
DF
-
Not greater than 150 percent of initial requirement.
2