MIL-DTL-3965/24C
Low temperature (storage):
DCL (max): See table I (25°C).
ĆCap.: Within ± 5 percent of initial measurement.
DF (max): See table I.
Stability at low and high temperature:
Step 1 (+25°C):
DCL (max): See table I.
Cap.: Within tolerance of table I value.
DF (max): See table I.
Step 2 (-55°C):
Impedance: See table I.
ĆCap. (max): See table I.
Step 3 (+25°C):
DCL (max): See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF (max): See table I.
Step 4(+85°C):
DCL (max): See table I.
ĆCap (max): See table I.
DF (max): See table I.
Step 5 (+125°C):
DCL (max): See table I.
ĆCap. (max): See table I.
DF (max): See table I.
11