MIL-DTL-3965/20F
Step 3 (+25°C):
DCL (max): See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF (max): See table I.
Step 4 (+85°C):
DCL (max): See table I.
ĆCap (max): +30 percent (≤ 20 V) or +20 percent (> 20 V) of step 1 value.
DF (max): See table I.
Step 5 (+125°C):
DCL (max): See table I.
ĆCap. (max): +30 percent (≤ 18 V) or +20 percent (> 18 V) of step 1 value.
DF (max): See table I.
Step 6 (+25°C):
DCL (max): See table I.
ĆCap.: Within ±5 percent of initial measurement.
DF (max): See table I.
Reverse voltage: Not applicable.
Life at +85°C:
2,000-hr (qualification):
DCL (max): See table I (25°C).
ĆCap.: Within ±15 percent of initial measurement.
DF (max): See table I (25°C).