MIL-DTL-3965/19F
Step 6 (+25°C):
DCL (max): See table I.
ĆCap.: Within ±5 percent of initial measurement.
DF (max): See table I.
Reverse voltage: Not applicable.
Life at +85°C:
Qualification (2,000 hours):
DCL (max): See table I (25°C).
ĆCap.: Within ±20 percent of initial measurement.
DF (max): See table I.
Quality conformance:
240 hours:
DCL (max): See table I (25°C).
ĆCap.: Within ±10 percent of initial measurement.
DF (max): See table I.
1,760 hours:
DCL (max): See table I (25°C).
ĆCap.: Within ±20 percent of initial measurement.
DF (max): See table I.
Barometric pressure:
Test voltage: Rated voltage for 30 V to 360 V units; 500 V dc for 540 V and 630 V.
Life at +125°C.
DCL (max): See table I (25°C).
ĆCap.: Within ±20 percent of initial measurement.
DF (max): 150 percent of initial requirement.