MIL-DTL-3965/1J
Low temperature (storage):
DCL (max): See table I (25°C).
ĆCap.: Within ± 5 percent of initial measurement.
DF (max): See table I.
Stability at low and high temperature:
Step 1 (+25°C):
DCL (max): See table I.
Cap.: Within tolerance of table I value.
DF (max): See table I.
Step 2 (-55°C):
Impedance: See table I.
ĆCap. (max): -60 percent (20 V), -45 percent (30 V), or 35 percent (>30 V) of step 1 value.
Step 3 (+25°C):
DCL (max): See table I.
ĆCap.: Within ±5 percent of step 1 value.
DF (max): See table I.
Step 4 (+85°C):
DCL (max): See table I.
ĆCap (max): +15 percent (≥ 30 V) or +10 percent (> 30 V) of step 1 value.
DF (max): See table I.
Step 5 (+125°C):
DCL (max): See table I.
ĆCap. (max): +20 percent (≥ 26 V) or +10 percent (>26 V) of step 1 value.
DF (max): See table I.
7