MIL-C-39018/10B
Step 2 (at -55°C):
Impedance: See table I.
Cap.: Within the following percentages of the step 1 value:
5 V dc: ±35 percent.
10 to 25 V dc inclusive: ±25 percent.
30 to 100 V dc inclusive: ±20 percent.
150 V dc: ±30 percent.
Step 3 (at +25°C):
DCL: See table I.
Cap.: Within ±5 percent of step 1 value.
ESR: See table I.
Step 4 (at +105°C):
DCL: See table I.
Cap.: Within ±30 percent of step 1 value.
ESR: See table I.
Step 5 (at +25°C):
DCL: See table I.
Cap.: Within ±5 percent of step 1 value.
ESR: See table I.
For qualification: Condition F (2,000 hours) at 85°C.
DCL: See table I.
Cap.: Within ±10 percent of initial measured value.
ESR: Not more than 130 percent of initial requirement.
10,000 hour (extended life and group C) at 85°C.
DCL: See table I.
Cap.: Within ±15 percent of initial measurement.
ESR: Not more than 250 percent of initial requirement.