MIL-C-39018/10B
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Case:
Type: Tubular.
Material: Metal.
Terminals: See figure 1.
DC rated voltage: See table I.
Reverse voltage: 1.5 volts maximum.
Capacitance (Cap.) value: See table I.
Cap. tolerance: -10, +75 percent.
FR level: M, P, R, and S.
Operating temperature range: -55°C to +105°C
Burn-in: In accordance with MIL-PRF-39018.
DC leakage (DCL), see table I.
Equivalent series resistance (ESR): See table I.
Low temperature exposure:
DCL: See table I.
Cap.: See table I.
ESR: See table I.
Terminal strength: Method 211 of MIL-STD-202, test condition E.
Torque: 8 inch-pounds for terminal style A; 15 inch-pounds for terminal style B.
Stability at reduced and high temperatures:
Step 1 (at +25°C):
DCL: See table I.
Cap.: See table I.
ESR: See table I.
8
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business