MIL-C-39018/10B
Case insulation: In accordance with MIL-PRF-39018.
Shock (specified pulse): Method 213 of MIL-STD-202, condition H.
Vibration: Low frequency: In accordance with MIL-PRF-39018.
Thermal shock and immersion:
Thermal shock: Method 107 of MIL-STD-202, condition A, except in step 3, units shall be tested at applicable
high temperature.
Immersion: Method 104 of MIL-STD-202, condition B (2 cycles, 30 minutes).
DCL: See table I.
Cap.: Within ±5 percent of initial measured value.
ESR: See table I.
Case insulation: Shall meet initial requirements.
Surge voltage:
DCL: See table I.
Cap.: Within ±6 percent of initial measured value.
ESR: See table I.
Vent: In accordance with MIL-PRF-39018.
Moisture resistance: Method 106 of MIL-STD-202.
DCL: See table I.
Cap.: Within ±6 percent of initial measured value.
ESR: See table I.
Case insulation: Shall meet initial requirements.
High temperature exposure (500 hours at 105°C):
DCL: Not more than 200 percent of initial requirement.
Cap.: Within ±10 percent of initial measured value.
ESR: Not more than 115 percent of initial requirement.
AC verification:
DCL: See table I.
Cap.: Within ±15 percent of initial measured value.
ESR: 200 percent of initial requirement.