MIL-PRF-83500/1C
240 hours (group B):
DCL (max): See table I (+85°C and +25°C).
ĆCap.: Within ±10 percent of initial measurement.
DF (max): Shall not exceed initial requirement.
6,000 and 10,000 hours (group C):
DCL (max) at +85°C: Shall not exceed 125 percent of +25°C value of table I.
DCL (max): See table I (+25°C).
ĆCap.: Within +10 percent, -20 percent of initial measurement.
DF (max): 150 percent of initial requirement.
Life at +125°C:
DCL (max): See table I (+125°C and +25°C).
ĆCap.: Within +10 percent, -20 percent of initial measurement.
DF (max): 150 percent of initial requirement.
Vacuum life at +125°C:
DCL: See table I (+125°C and +25°C).
ĆCap.: Within ±20 percent of initial measurement.
DF: See table I.
Weight loss: 4.1 milligrams maximum.
AC ripple life at +125°C:
DCL (max): See table I (+125°C and +25°C).
ĆCap.: Within ±15 percent of initial measurement.
DF (max): See table I.
Marking: In accordance with MIL-PRF-83500.
Part or Identifying Number (PIN): M83500/01- (dash number from table I).
Polarity: Plus (+) symbol marked on positive terminal.
6