MIL-PRF-39018/2F
Life: Method 108 of MIL-STD-202.
For qualification: Condition F (2,000 hours) at +85°C.
DCL -: See table I.
ĆC - Within 15 percent of initial measured value.
ESR Not more than 130 percent of initial requirement.
For conformance: Performance check, condition B (250 hours) at +85°C.
DCL -: See table I.
ĆC - Within 10 percent of initial measured value.
ESR - See table I.
For conformance: Continuation test (1,750 hours) at +85°C.
DCL - See table I.
ĆC - Within 15 percent of initial measured value.
ESR - Not more than 130 percent of initial requirement.
Vibration:
High frequency: In accordance with MIL-PRF-39018.
*
Thermal shock and immersion:
Thermal shock: Method 107 of MIL-STD-202, condition A, except that in step 3 units shall be tested at the
applicable high temperature.
Immersion: Method 104 of MIL-STD-202, condition B (2 cycles, 30 minutes).
DCL: See table I.
ĆC: Within 5 percent of initial measured value.
ESR: See table I.
Insulation resistance of sleeve: Not less than 100 megohms.
Surge voltage:
DCL: See table I.
ĆC: Within 6 percent of initial measured value.
ESR: See table I.
Moisture resistance: Method 106 of MIL-STD-202.
DCL: See table I.
ĆC: Within 6 percent of initial measured value.
ESR: See table I.
Insulation resistance of insulating sleeve: Not less than 100 megohms.
High temperature exposure: (500 hours at +125°C)
DCL: Not more than 200 percent of initial requirement.
ĆC: Within 10 percent of initial measured value.
ESR: Not more than 115 percent of initial requirement.
Reverse voltage: Not applicable.
Penetration of solvents: In accordance with MIL-PRF-39018.
High temperature verification: In accordance with MIL-PRF-39018 at +125°C with derated voltage applied: