MIL-PRF-39003/2J
Surge voltage: In accordance with MIL-PRF-39003.
DCL: See table I.
Capacitance: Shall not change more than ± 2 percent from initial measured value.
DF: See table I.
Life: Method 108 of MIL-STD-202.
240, 1,000, and 2,000 hours.
At 25°C (as applicable).
DCL: See table I.
Capacitance: Not greater than ± 5 percent of initial measured value.
DF: See table I.
At 85°C:
DCL: See table I.
At 125°C:
DCL: See table I.
4,000, 6,000, 8,000, and 10,000 hours (exponential only):
At +25°C (as applicable):
DCL: 200 percent of initial limit.
Capacitance: Not greater than ± 10 percent of initial measured value.
DF: See table I.
At +85°C:
DCL: 200 percent of initial limit.
At +125°C:
DCL: 200 percent of initial limit.
Marking: In accordance with MIL-PRF-39003.
Part or Identifying Number (PIN): M39003/02-(dash number from table I).
Substitutability data: Substitutability for failure rate levels and capacitance tolerances shall be in accordance with
MIL-PRF-39003.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business