MIL-PRF-39003/2J
REQUIREMENTS Continued:
Stability at low and high temperatures: In accordance with MIL-PRF-39003.
Step 1 (+25°C):
DCL: See table I.
Capacitance: Within tolerance of table I value.
DF: See table I.
Step 2 (-55°C):
Capacitance: Shall not change more than ± 8 percent of step 1 measured value.
DF: See table I.
Step 3 (+25°C):
DCL: See table I.
Capacitance: Shall not change more than ± 2 percent of step 1 measured value.
DF: See table I.
Step 4 (+85°C):
DCL: See table I.
Capacitance: Shall not change more than ± 8 percent of step 1 measured value (6, 10, and 15 volt units).
Capacitance: Shall not change more than ± 6 percent of step 1 measured value (20 volts and higher).
DF: See table I.
Step 5 (+125°C):
DCL: See table I.
Capacitance: Shall not change more than ±12 percent of step 1 measured value.
DF: See table I.
Step 6 (+25°C):
DCL: See table I.
Capacitance: Shall not change more than ± 2 percent of step 1 measured value.
DF: See table I.