MIL-C-62/5D
Moisture resistance: Method 106 of MIL-STD-202.
Insulation resistance (Insulating sleeve): Not less than 100 megohms.
DWV: Insulating sleeves - Method 301 of MIL-STD-202. 4, 000 volts dc applied.
DCL: Not more than 150 percent of initial requirement.
Capacitance change: 5 percent.
DF: See table I.
Corrosion: Not more than 10 percent.
Stability at low and high temperature: In accordance with MIL-C-62.
Step 1 (at +25°C):
DCL: See table I.
Capacitance: See table I.
DF: See table I.
Step 2 (at -40°C):
Impedance: See table I.
Step 3 (at +25°C):
DCL: See table I.
Capacitance: ±5 percent of initial value.
DF: See table I.
Step 4 (at +85°C):
DCL: Not more than 10 times initial value, or meet initial 25°C requirements.
Capacitance: ±20 percent of initial value.
DF - See table I.
Step 5 (at +25°C):
DCL: See table I.
Capacitance: ±5 percent of Initial value.
DF - See table I.
5