MIL-C-62/5D
REQUIREMENTS:
Case type: Tubular.
Capacitance value: See table I.
Capacitance tolerance:
At 200 volts, dc rated, and above: -10, +50 percent.
At 150 volts, dc rated, and less: -10, +75 percent.
Operating temperature range: -40°C to +85°C.
Solderability: Method 208 of MIL-STD-202.
DC leakage: See table I.
Capacitance: Method 305 of MIL-STD-202.
Dissipation factor: See table I.
Terminal strength: Method 211 of MIL-STD-202, test conditions A, B, and E.
Shock (specified pulse): Method 213 of MIL-STD-202, test condition I.
Vibration, high frequency: Method 204 of MIL-STD-202, test condition B.
Salt atmosphere (corrosion): Method 101 of MIL-STD-202, test condition B.
Temperature cycling and Immersion:
Thermal shock: Method 107 of MIL-STD-202, test condition A.
Immersion: Method 104 of MIL-STD-202, test condition C.
DWV: Insulating sleeves - Method 301 of MIL-STD-202. 4,000 volts dc applied.
DCL: Not more than 150 percent of initial measurement.
Capacitance change: 5 percent.
DF: See table I.
Corrosion: Not more than 10 percent.
4