MIL-C-62/10E
Surge voltage: In accordance with MIL-C-62.
DCL: See table I.
Capacitance change: 6 percent.
DF: See table I.
Vent: Not applicable.
Life: Method 108 of MIL-STD-202, test condition F.
DCL: See table I.
Capacitance change:
100 volts, dc rated, and less: -20, +15 percent.
DC rated voltage above 100 volts: ± 15 percent.
DF: Meet the initial requirement or not exceed 150 percent of the initial measurement.
Barometric pressure: Method 105 of MIL-STD-202.
Shelf life: in accordance with MIL-C-62.
Build factor: Not more than 4.0.
Shelf factor: Not more than 3.0.
DCL; Not more than 150 percent of initial value.
Capacitance change: 6 percent.
DF: Not more than 175 percent of initial requirement.
Application data:
All capacitors shall withstand an rms ripple current at 120 Hz and 85 ° C as determined from the formula:
Ir = k c
Where:
Ir =
rms ripple current in milliamps.
C =
nominal capacitance in microfarads per section.
k =
45 for units rated at 0 to 150 volts dc, inclusive.
=
35 for units rated at 300 to 350 volts dc, inclusive.
=
30 for units rated at 300 to 350 volts dc, inclusive.
=
25 for units rated at 400 to 450 volts dc, inclusive.
Supersession data: See table II.
6