MIL-C-62/10E
Moisture resistance: Method 106 of MIL-STD-202.
Insulation resistance (insulating sleeve): Not less than 100 megohms.
DWV (insulating sleeves): Method 301 of MIL-STD-202. 4,000 volts dc applied.
DCL: Not more than 150 percent of initial requirement.
Capacitance change: 5 percent.
DF: See table I.
Corrosion: Not more than 10 percent.
Stability at low and high temperature: In accordance with MIL-C-62.
Step 1 (at +25°C):
DCL: See table I.
Capacitance: See table I.
DF: See table I.
Step 2 (at -40°C):
Impedance: See table I.
Step 3 (at +25°C):
DCL: See table I.
Capacitance: ±5 percent of initial value.
Step 4 (at + 85°C):
DCL: Not more than 10 times initial value, or meet initial 25° C requirement.
Capacitance: ± 20 percent of initial value.
DF: See table I.
Step 5 (at + 25°C):
DCL: See table I.
Capacitance: ± 5 percent of initial value.
DF: See table I.
5