MIL-C-62/1D
Stability at low and high temperature:
In accordance with MIL-C-62.
Step 1 (at +25C):
DCL - See table I.
Capacitance - See table I.
DF - See table I.
Step 2 (at -40C):
Impedance - See table I.
Step 3 (at +25C):
DCL - See table I.
Capacitance - +5 percent of initial value.
DF - See table I.
Step 4 (at +85C):
DCL - Not more than 10 times initial value, or meet initial 25C requirement.
Capacitance - 20 percent of initial value.
DF - See table I.
Step 5 (at +25C):
DCL - See table I.
Capacitance - 5 percent of initial value.
DF - See table I.
Surge voltage:
In accordance with MIL-C-62.
DCL - See table I.
Capacitance change - 6 percent.
DF - See table I.
Vent: Not applicable.