MIL-C-11015/4D
REQUIREMENTS
Design and construction:
Dimensions and configuration - See figure 1.
Case type - Tubular with radial leads.
Capacitance value - See table I.
Capacitance tolerance -
10 percent (K) or 20 percent (M) as shown in table I.
Rated temperature - -55 C to +85 C.
Dielectric withstanding voltage: In accordance with MIL-C-11015.
Dielectric:
Test voltage - 250 percent of rated voltage.
Body insulation: Shall be able to withstand 1,300 volts for 5 1 second between leads and a V-block which
shall extend beyond the ends of the capacitor body.
Barometric pressure (reduced): In accordance with MIL-C-11015 and method 105 of MIL-STD-202, 0.82 inch of
mercury (80,000 ft).
Test potential - 150 percent of rated voltage.
Insulation resistance (IR): In accordance with MIL-C-11015 and method 302 of MIL-STD-202, condition B.
20,000 megohms, minimum.
Dissipation factor (DF): 1.5 percent, maximum.
Shock, specified pulse: Not applicable.
Vibration, high frequency: In accordance with MIL-C-11015 and method 204 of MIL-STD-202, condition B
(15 g's).
Thermal shock and immersion: In accordance with MIL-C-11015.
IR - 3,000 megohms, minimum.
Salt spray (corrosion): Not applicable.
Terminal strength: In accordance with MIL-C-11015.
Moisture resistance: In accordance with MIL-C-11015.
IR - 3,000 megohms, minimum.
Solderability: In accordance with MIL-C-11015; 2 terminals.
Resistance to soldering heat: Not applicable.
2