MIL-C-11015/20D
REQUIREMENTS:
Design and construction:
Dimensions and configuration: See figure.
Case type - Tubular molded or preformed plastic encapsulated with axial leads.
Capacitance value - See table I.
Capacitance tolerance -
10 percent (K) or 20 percent (M) as shown in table I.
Rated temperature - -55 C to +125 C
Dielectric withstanding voltage (DWV): In accordance with MIL-C-11015.
Dielectric:
Test voltage - 250 percent of rated voltage.
Body insulation: Not applicable.
Barometric pressure (reduced): In accordance with MIL-C-11015 and method 105 of MIL-STD-202, test condition
D (100,000 ft) (0.315 inch (8.00 mm) of mercury).
Test potential - 150 percent of rated voltage.
Insulation resistance (IR): In accordance with MIL-C-11015; rated voltage applied.
100,000 megohms, min or 1,000 megohm-microfarads, min, whichever is less.
Dissipation factor (DF): 2.5 percent, max.
Vibration, high frequency: In accordance with MIL-C-11015 and method 204 of MIL-STD-202, condition D
(20 g's).
Thermal shock and immersion: In accordance with MIL-C-11015.
DWV - 250 percent of rated voltage.
IR - Not less than 50 percent of initial 25 C requirement.
Cap. - Within 10 percent of initial measured value.
DF - 2.5 percent, max.